Waveform Timestamps VIs

Align Waveform Timestamps DBL

Align Waveform Timestamps DBL VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

Align Waveform Timestamps DBL

Align Waveform Timestamps CXT VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

Align Waveform Timestamps DBL

Align Waveform Timestamps CDB VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

WDT Align Waveform Timestamps I64

Align Waveform Timestamps I32 VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

WDT Align Waveform Timestamps I64

Align Waveform Timestamps I16 VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

General Error Handler VI

General Error Handler VI

This VI indicates whether an error occurred. If an error occurred then this VI returns a description of the error and optionally displays the dialog box. [user-defined descriptions] is an array of descriptions of user-defined codes. If an incoming error matches one inuser-defined codes, the VI returns the corresponding description from user-defined descriptions in message [user-defined codes] is […]

WDT Align Waveform Timestamps I64

Align Waveform Timestamps I64 VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

DWDT Align Waveform Timestamps

DWDT Align Waveform Timestamps VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

Align Waveform Timestamps DBL

Align Waveform Timestamps EXT VI

Change all the time stamp values (t0) in “waveforms in” with the value of the “index” element in the array. The data type you wire to the “waveforms in” input and the data type of the Y component of the analog waveform establish the polymorphic instance to use. Waveforms in contains all the analog waveforms for which time stamps (t0) […]

status is TRUE (X)

Using the Standard Functionality “Error Out Parameters” in VIs

LabVIEW nodes like the VIs and the functions contain an “error out parameter”. These are used to set up an error I/O in VIs in order to manage errors in VIs. These parameters typically give the same standard functionality. When a node exhibits different parameter functionality, the exceptions are documented in the reference material for that node. […]

source specifies

Using the Standard Functionality for “Error In Parameters” in VIs

LabVIEW nodes like the VIs and the functions contain an “error out parameter”. These are used to set up an error I/O in VIs in order to manage errors in VIs. These parameters typically give the same standard functionality. When a node exhibits different parameter functionality, the exceptions are documented in the reference material for that node. […]