NI Software Calibration Management Toolkit for LabVIEW 2013 User Manual

NI Software Calibration Management Toolkit for LabVIEW 2013 User Manual
Pages 100
Views 1,023
Downloads : 2 times
PDF Size : 2.0 MiB

Summary of Contents

NI Software Calibration Management Toolkit for LabVIEW 2013 User Manual

  • Page 1

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 1 NI Software Calibration ManagementToolkit for LabVIEW™ 2013User's Manual Web actionURI(http://www.ni.com/powertrain-controls/):: http://www.ni.com/powertrain-c...

  • Page 2

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 2Table of Contents 4,1. Product Introduction 4, ........... 4,................................................................................................................

  • Page 3

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 3 82,6.11 Unit Conversions 82, ............ 82,................................................................................................................82 85,6.12 U...

  • Page 4

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 41. Product IntroductionThe NI Software Calibration Management Toolkit for LabVIEW 2013 is a calibration interface toolkit for efficientlycommunicating and calibrating dat...

  • Page 5

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 5• User-specified unit conversions managed on host• User-specified default units and exceptions• Drag-and-drop, keyboard, or automatic CalPoint pairing• User inter...

  • Page 6

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 62. Getting Started

  • Page 7

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 72.1 Recommended System Requirements Note: System requirements will vary based on many factors including:• Number of CalPoints• Communication Rate• Other Running Pro...

  • Page 8

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 82.1 Installing NI SCMFor more information on the NI Software Calibration Management Toolkit for LabVIEW, please visit actionURI(http://www.ni.com/powertrain-controls/):ht...

  • Page 9

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 92.2 Activating Your SoftwareActivating Your SoftwareThis section describes how to use the NI Activation Wizard to activate your software. How Do I Activate My Software?Us...

  • Page 10

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 10 What is a Computer ID? The computer ID contains unique information about your computer. National Instruments requires this informationto enable your software. You can f...

  • Page 11

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 113. NI SCM PalettesNI SCM installs two types of palettes into NI LabVIEW, the first is the 13,functions palettes 13, which contain allthe subVIs required to create a NI ...

  • Page 12

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 124. NI SCM Target

  • Page 13

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 134.1 Functions PaletteThe NI SCM functions palette (block diagram), found under "Powertrain Controls\Software CalibrationManagement", consists of VIs that can b...

  • Page 14

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 14Target Utilities PaletteRead CalFile.viThis VI reads the data from a calibration file. It may be used on the target to evaluate calibration data. Save CalFile.viThis VI...

  • Page 15

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 15 Save Fault File.viThis VI saves a Fault file in the default data directory. "Fault File" should be set to the desired Fault filename without a file extensio...

  • Page 16

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 16Host Utilities Palette SCM Console Button.viThis VI is to be used in the host VI and "presses" some of the buttons on the SCM console as if the userpresses the...

  • Page 17

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 17 CalPoints Palette Each type of CalPoint has a variety of parameters that are configured through a configuration dialog. Some types of CalPoints can programmatically ad...

  • Page 18

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 18Fault points are used to manage fault conditions. The faults have 3 different target operations. Set, get,and clear which can be used to control the fault state. Fault P...

  • Page 19

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 194.2 Basic FrameworkA NI SCM target VI must use a basic framework in order to work properly. The framework starts with theSCM Init VI controlling a case structure. The ca...

  • Page 20

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 204.3 SCM Init VI SCM Init The SCM Init VI must be used once and only once in the top level target VI. The SCM Init VI is an expressVI and serves two main functions. The...

  • Page 21

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 21 The summary table contains a list of all the CalPoints found within the target along with most of theirproperties. The list is sorted in alphabetical order based on th...

  • Page 22

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 22SCM Init CalPoint Statistics The Stats tab in the SCM Init dialog contains a summary of CalPoint distributions. Distributions based ondata type, group, class, and ownin...

  • Page 23

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 23SCM Init Adapt Point Summary The Adapt tab displays a list of all the Adapt Points found in the project. The associated type and IDnumber are also displayed to allow ea...

  • Page 24

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 24SCM Init CalScope Setup The CalScope tab contains the base setup for the CalScope controls. The user specifies the total numberof scopes (up to 8) desired. Each scope ...

  • Page 25

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 25SCM Init A2L File Setup The SCM Init dialog can export the CalPoint table to an A2L file. The A2L file can be imported to a test cellsupervisory system which supports A...

  • Page 26

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 26SCM Deploy: Selecting SCM Deploy forces the user to deploy the VI from the NI SCM consol. Thisguarantees that SCM Init runs before deploying. If the target is deployed ...

  • Page 27

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 274.4 Specifying the Calibration FileThe “Calibration File” input to the SCM Init and Control SCM VIs may be one of two formats. Thoseformats are referred to as Direc...

  • Page 28

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 283. The user must understand and accept the risk of loading the calibration file on a running target.

  • Page 29

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 294.5 CalPointsEach CalPoint is a single point on the block diagram used to instrument the real-time application. CalPoints are Express VIs and have a popup configuration ...

  • Page 30

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 304.6 Reserved CalPointsNI SCM automatically reserves a number of CalPoints at the beginning of the CalPoint list. TheseCalPoints contain properties of the target and hos...

  • Page 31

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 314.7 CalPoint Configuration DialogsBelow is the common property fields associated with each CalPoint. Name: CalPoint name. Group: CalPoint group. Class: CalPoint class...

  • Page 32

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 324.7.1 SGL, I32, I8, U32, U8 CalPointsThe CalPoint configuration dialog box the figure below is representative of SGL, I32, I8, U32, and U8 datatypes (SGL shown). Limits ...

  • Page 33

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 334.7.2 Array CalPointsThe Array CalPoint contains the property fields as shown in the figure below. The array indicator andcontrol CalPoint assumes a default value of ze...

  • Page 34

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 344.7.3 String CalPointsThe String CalPoint contains the property fields as shown in the figure below. A String CalPoint does nothave units. Like the array CalPoints, the...

  • Page 35

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 354.7.4 Boolean CalPointsThe Boolean CalPoint contains the property fields as shown in the figure below. A Boolean CalPointdoes not have units, but instead has True and F...

  • Page 36

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 364.7.5 Lookup Table CalPointsThe Lookup Table CalPoint contains the property fields as shown in the figures below. The 1D and2D lookup table units are split into 2 and 3...

  • Page 37

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 374.7.6 Enumerated CalPointsThe Enumerated CalPoint contains the property fields as shown in the figure below. The enumeratedCalPoint provides an array field for specifyi...

  • Page 38

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 384.8 Adapt PointsWith CalPoint controls by themselves, only the host user interface can modify their values. Adapt Pointsallow the target program to modify CalPoint contr...

  • Page 39

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 394.9 Fault PointsFault points have 3 target operations. The first is to set the fault. The fault is based on an up/down counterwhich allows the programmer to specify a de...

  • Page 40

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 40Down Rate: The value at which the up/down counter decreases each time the fault set is called and theinput is set to false. Sticky: Enable a sticky fault. The fault will...

  • Page 41

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 414.10 Real-Time Target SetupNational Instrument real-time targets use one of three real-time operating systems. The real-time targetsmust be configured with the appropria...

  • Page 42

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 424.11 Building Startup Executable Applications with NI SCMApplications which use NI SCM can be built into a startup application similar to any other application. Theuser...

  • Page 43

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 434.12 Backup and Restore of a Real-Time SystemNI SCM provides a resource for backing up and restoring real time targets. The tool uses the NI SystemConfiguration tools pr...

  • Page 44

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 44RT Restore Target IP Address: Specifies the IP address of the target needing a restored. Target Description: Displays information about the controller (ex. Type). Back...

  • Page 45

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 455. NI SCM HostThe host VI is a VI created by the project programmer and acts as the operator interface to the target. The main requirement for the host VI is that it mu...

  • Page 46

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 46Value (signaling) Property Node When changes are made to the host VI, the NI SCM console needs to be refreshed in order to be madeaware of those changes. When the “Sta...

  • Page 47

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 475.1 Controls PaletteThe NI SCM controls palette (front panel), found under "Powertrain Controls\Software CalibrationManagement", consists of controls that can ...

  • Page 48

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 485.2 Lookup Table ControlsNI SCM uses custom XControls to display Lookup Tables on the host VI. The XControl allows advancedviewing and editing options. The control dis...

  • Page 49

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 495.2.1 1D Tables1D tables consist of a set of matching X and Y arrays. The X values correspond to the input and the Yvalues correspond to the output values. The figures...

  • Page 50

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 50 Modify Format String: Changes the format of numbers displayed in the table. Enter a valid format string. Please actionURI(http://www.ni.com):see www.ni.com for details...

  • Page 51

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 51to subtracting the first selected value from the array, scaling the array and then adding the original value tothe array. This may be useful if the slope of the table n...

  • Page 52

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 525.2.2 2D Tables2D tables consist of a set of interacting X, Y and Z arrays. The X and Y values correspond to the inputsand the Z values correspond to the output values....

  • Page 53

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 53Modify Format String: Changes the format of numbers displayed in the table. Open Plot Window: Opens a popup window with a plot of the table and the current value. Show...

  • Page 54

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 545.3 CalScopeCalScopes allow the user to dynamically setup and run CalPoint plots. The number of plots and theirassociated memory use must be configured in SCM Init fro...

  • Page 55

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 55CalScope The CalScope plot window contains the rest of the scope setup and control. Active Channel: Selecting a CalPoint from the Active Channel drop-down list will disp...

  • Page 56

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 56 Save Data To File: Saves the current plot capture to the specified file. Files may be stored in a TDMS orCSV format according to the TDMS/CVS button text shown. Run/St...

  • Page 57

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 575.4 CalTrendCalTrends provide plotting and configuration similar to CalScopes. The primary difference is thatCalTrends do not need to be configured in SCM Init and they...

  • Page 58

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 58Trend Plot The trend popup window provides all the remaining configurations for the trends. Active Channel: Selecting a CalPoint from the Active Channel drop-down list w...

  • Page 59

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 595.5 FaultsFaults are displayed and control using the Faults XControl. The user simply needs to add a single FaultsXControl to the host VI and the console will automatic...

  • Page 60

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 605.6 Other Host VI ToolsThe NI SCM controls palette contains several XControls to help make powerful and easy to setup userinterfaces. These XControl were specifically de...

  • Page 61

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 616. NI SCM ConsoleThe NI SCM console application for Microsoft Windows can be found at Start > All Programs > NationalInstruments > Software Calibration Manageme...

  • Page 62

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 62target location has been specified, it can be confirmed by dropping down the File menu at the top of theconsole. The target name and/or IP address will be listed in par...

  • Page 63

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 63 Messages: This window reports messages associated with NI SCM actions, warnings or errors. Warnings and errors are color coded. Each message is time-stamped and the ...

  • Page 64

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 646.1 Menu Items•File:•Select Target (…): Opens the Select Target dialog.•Select Hosts (…): Opens the Select Host VI dialog.•Save Pairings: Saves the pairing f...

  • Page 65

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 65•Save Calibration: Saves the default calibration file to the target. The filename is specified bythe “Calibration File” input to the SCM Init VI and is placed in ...

  • Page 66

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 666.2 NI SCM ControlsSome controls are enabled and disabled automatically according to context. Refresh Target Items, Host Items, and PairingsStarts the host application a...

  • Page 67

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 676.3 Mini Mode NI SCM Console Mini Mode The NI SCM console mini mode contains small versions of the NI SCM console controls and the mostrecent message from the message wi...

  • Page 68

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 686.4 SCMConfig.ini The SCMConfig.ini file contains user preferences and settings. The file is located in the “c:\Program Files\National Instruments\SCM 2013\Resources...

  • Page 69

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 69TARGET_NEXTz,Num-EndStringHOST_UPw,Num-UpStringHOST_DOWNs,Num-ClearStringHOST_NEXTx,Num-DownStringPAIR_UPe,Num-PageUpStringPAIR_DOWNd,Num-RightStringPAIR_NEXTc,Num-PageD...

  • Page 70

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 706.5 Saving and Loading NI SCM settings A NI SCM settings file may be created with the utility shown in the figure below This utility is opened byselecting "Save SC...

  • Page 71

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 71Saving NI SCM Setting Some of the parameters stored in the .cvsf are similar to those in the SCMConfig.ini file (TargetAddress,HostVI, etc.). SCMConfig.ini is always re...

  • Page 72

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 72and the settings in the .cvsf file will override similar settings in SCMConfig.ini. This is useful for creatingdifferent .cvsf files for different projects so that a SC...

  • Page 73

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 736.6 Finding a Target The user must specify the location of the real-time target to NI SCM by selecting the “Select TargetMachine” option in the File menu. The user ...

  • Page 74

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 74 The .hsf file is an ini file with a Host group and three properties. The three properties are Host, Pairings,and Units. The Host and Pairing properties are lists of fil...

  • Page 75

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 75Target Simulation

  • Page 76

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 766.7 Pairing CalPoints After the user has selected a host VI and a target, the NI SCM console program allows the user to pairhost controls and indicators to the CalPoints...

  • Page 77

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 776.8 Taking a Snapshot NI SCM has the ability to take a snapshot of the current values of specified host items (excluding tablesand arrays). The snapshot is stored in a ...

  • Page 78

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 786.9 CalDiff (Calibration File Difference) CalDiff is a calibration file differencing utility that allows a user to easily compare and modify calibrationfiles. The utili...

  • Page 79

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 79Opens the Calibration File Manager (displays and sets viewed files) Closes the calibration differencing tool

  • Page 80

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 806.10 Calibration File Manager The calibration file manager is used to copy files between the target and host machines. The file managerstarts from the NI SCM console or ...

  • Page 81

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 81When opened from the NI SCM console while communicating with a target, the “Target File” indicates thecurrent calibration file on the target. It may also be used to ...

  • Page 82

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 826.11 Unit Conversions Each CalPoint provides a field for specifying the engineering units of the parameter. In order to displaythe units along with the graphical contro...

  • Page 83

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 83Unit Editor The unit editor allows the user to add/remove unit conversions, add/remove unit classes, modify theunit conversions, and change the default display unit. Dou...

  • Page 84

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 84Edit Unit Conversion

  • Page 85

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 856.12 Unit Conversion Rules Unit conversions follow some simple rules.• If host VI controls/indicators caption fields contain brackets, braces, or parentheses, then the...

  • Page 86

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 866.13 Example of Unit Conversions# Assumed Target Units: “psi”# Assumed Default Unit: “kPa”# … refers to any characterEditable Host VICaption Contai...

  • Page 87

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 877. Simple Example

  • Page 88

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 887.1 Basic Project ExampleA NI LabVIEW project which implements NI SCM should contain a real-time target with a real-time VI asshown in the figure below. The following e...

  • Page 89

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 89Basic NI SCM Project Example Real-Time VI

  • Page 90

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 908. TroubleshootingA Microsoft Windows Help file (.chm) for NI SCM Software is provided with the software download. The file and beopened using the start menu. Frequently...

  • Page 91

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 91A: An enumerated item on the host VI must have the same number of enumerated items as the CalPoint. Thestring for each enumerated item on the host does not matter b...

  • Page 92

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 92A: The target and host times are set using the universal time stamp. If the target time zone is different than thehost time zone, the two will have local times that ...

  • Page 93

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 939. Additional Support/Feedback Please contact NI Systems Support at 210-248-9308 or actionURI(mailto:powertraincontrolsinfo@ni.com):powertraincontrolsinfo@ni.com. For ad...

  • Page 94

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9410. Important Information

  • Page 95

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9510.1 WarrantyRemove the following paragraph for software products. NI SCM Software is warranted against defects in materials and workmanship for a period of one year fro...

  • Page 96

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9610.2 CopyrightUnder the copyright laws, this publication may not be reproduced or transmitted in any form, electronic ormechanical, including photocopying, recording, st...

  • Page 97

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9710.3 TrademarksRefer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instrumentstrademarks. ARM, Keil, and µVision are tr...

  • Page 98

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9810.4 PatentsFor patents covering the National Instruments products/technology, refer to the appropriate location: Help»Patents inyour software, the patents.txt file on ...

  • Page 99

    NI Software Calibration Management Toolkit for LabVIEW 2013User's Manual© 2013 National Instruments. All rights reserved. 9910.5 Warning Regarding Use of NI ProductsWARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS (1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TE...

  • Page 100