3.0 GHz Spectrum Analyzer GSP830 User Manual

3.0 GHz Spectrum Analyzer GSP830 User Manual
Pages 181
Views 1,652
Downloads : 1 times
PDF Size : 4.4 MiB

Summary of Contents

3.0 GHz Spectrum Analyzer GSP830 User Manual

  • GSP-830 User Manual 76 3. Press F1 (AVG On) to turn on the average mode. AVGOn Off 20F 1 4. The average mode icon appears at the bottom of the display. 5. Enter the average number using the Numerical keys and Enter key. BK SPdBEnterGHz /SecmSecMHz /kHz / Secμ Panel operation (Method2) 1. Press the BW key. BW 2. Press F4 (AVG On) to turn on averaging. AVGOn Off 20F 4 3. Enter the average time using the numerical keys and Enter key. BK SPdBEnterGHz /SecmSecMHz /kHz / Secμ Range 1 to 200 Example: after average Averaged 20 times Move Marker to Trace Panel operation 1. Check the active marker at the top right corner of the display. 2. Press the Marker key. Marker 3. Press F6 (More). MoreF 6 4. Press F1 (Marker Trace). Marker TraceAuto A B CF 1 Range Auto The marker moves to the active signal or trace.