3.0 GHz Spectrum Analyzer GSP830 User Manual

  • GSP-830 User Manual 42 View Signal (Center and Span) Center-and-Span method defines the center frequency and the left/right bandwidth (span) to locate the signal. Set frequency adjustment step Background Frequency adjustment step defines the Arrow keys resolution for center, start, and stop frequency. Panel operation 1. Press the Frequency key. Frequency 2. Press F4 (Step). Step1 MHzF 4 3. Enter the value using the Numerical and Unit keys, Arrow keys, and Scroll knob. BK SPdBEnterGHz /SecmSecMHz /kHz / SecμRange 0kHz to 3GHz * Arrow keys and Scroll knob resolution: 1/10 of Span Set center frequency Panel operation 1. Press the Frequency key. Frequency 2. Press F1 (Center). Center1.5 GHzF 1 3. Enter the value using the Numerical and Unit keys, Arrow keys, or Scroll knob. BK SPdBEnterGHz /SecmSecMHz /kHz / SecμRange 0kHz to 3GHz Arrow keys and Scroll knob resolution: step value Note Center frequency and span settings automatically change according to start and stop frequency settings, and vice versa.