3.0 GHz Spectrum Analyzer GSP830 User Manual

3.0 GHz Spectrum Analyzer GSP830 User Manual
Pages 181
Views 1,703
Downloads : 1 times
PDF Size : 4.4 MiB

Summary of Contents

3.0 GHz Spectrum Analyzer GSP830 User Manual

  • GSP-830 User Manual 166 meas:ocbw? Returns the OCBW activation/deactivation status. Parameter:on,off meas:ocbw Turns On/Off OCBW. Parameter: on, off Example: meas:ocbw_on meas:ocbw:bw? Returns the power measurement channel space in kHz. meas:ocbw:per? Returns OCBW percentage. meas:ocbw:per Sets OCBW percentage. Example: meas:ocbw:per_90 (90%) meas:ndb? Returns N dB activation status. Parameter: on, off meas:ndb Turns on/off N dB. Parameter: on, off Example: meas:ndb_on meas:nbw:ndb? Returns N dB bandwidth. Example: 1000 khz meas:nbw:ndb Sets N dB. Example: meas:ndb:ndb_3 (3 dB) meas:jitter? Returns Phase Jitter on/off status. Parameter: on, off meas:jitter Turns On/Off Phase Jitter. Parameter: on, off Example: meas:jitter_on meas:jitter:stoffs? Returns Phase Jitter start offset. Example: 0 khz meas:jitter:stoffs Sets Phase Jitter start offset. Need to specify the unit. Example: meas:jitter:stoffs_0_khz meas:jitter:stpoffs? Returns Phase Jitter stop offset. Example: 50 khz meas:jitter:stpoffs Sets Phase Jitter stop offset. Need to specify the unit. Example: meas:jitter:stpoffs_50_khz meas:jitter:phase? Returns Phase Jitter phase in radian. Example: 1.234 rad meas:jitter:time? Returns Phase Jitter time in pico second. Example: 1.234psec Limit line meas:lmtline:on Turns On limit line. Parameter: 0 (low limit line), 1 (high limit line) Example: meas:lmtline:on_0 (low limit line On) meas:lmtline:off Turns Off limit line. Parameter: 0 (low limit line), 1 (high limit line) Example: meas:lmtline:off_0 (low limit line Off) meas:lmtline:passfail? Returns Pass/Fail test result. Parameter: 0 (Fail), 1 (Pass) meas:lmtline:passfail Turns On/Off Pass/Fail test. Parameter: on, off Example: meas:lmtline:passfail_on (Pass/Fail test On) meas:lmtline: passfail:criterion? Returns Pass/Fail test criteria. Parameter: 1 (pass if all signals are in the zone), 2 (pass if the peaks are in the zone), 3 (pass if valleys are in the zone) meas:lmtline: passfail:criterion Sets Pass/Fail test criteria. Parameter: 1 (pass if all signals are in the zone), 2 (pass if the peaks are in the zone), 3 (pass if valleys are in the zone) Example: meas:lmtline:passfail:criterion_3 meas:lmtline:table? Returns limit line table On/Off. Parameter: on, off meas:lmtline:table Turns On/Off limit line table. Parameter: on, off Example: meas:lmtline:table_on (limit line table On)